Non-mydriatic Fundus Camera
- Non-mydriatic Photography
- Automatic Capture
- Automatic Chinrest Adjusting
- Automatic Focus and Exposure
- DICOM and AI System Available
Fully Automatic Fundus Camera
Maxter has launched this fully automatic, easy-to-use, and fast non-mydriatic fundus camera. It utilizes advanced soft exposure technology to reduce patient discomfort during image acquisition. It is a more practical fundus examination device in modern ophthalmology.
Modo de trabalho automático
Automatic Alignment and focusing of our auto fundus camera assist you in getting high-definition images with one key touch




Manual Working Mode
In cases where auto mode is not possible, or for special fundus photography, manual operation can help with alignment, focus, flash, and diopter compensation through screen touch.




Soft Lighting Technology
Soft lighting optical technology is adopted in our auto fundus camera to reduce the constriction of the pupil caused by the illumination. Satisfactory images can be obtained even in two consecutive exposures.

135° Wide Field
The mosaic function can generate a fundus image with a 135° field of view from 9 images, each with a 50° field width. More fixation points are distributed between the 9 fixações internas mostradas.

Non-Mydriatic Design
The fundus image can be acquired for pupils as small as 2.8mm, which is appropriate for patients with small pupils.


Dual-camera System
Dual-camera system is like eyes of the device. It searches and locates the pupil for fast and accurate autofocus.
Multifunctional Software System
- Powerful image processing function, to acquire the lesion area and disc ratio easily
- Gamma contrast, brightness, and color of the image can be adjusted according to doctor’s requirements

Fundus Cameras Application in Clinics and Hospitals




Our fully automatic fundus cameras are widely used in major hospitals, clinics, community hospitals and other medical institutions, providing doctors and patients with efficient and convenient ophthalmic diagnosis methods.
Fundus Camera Specifications
| Modos de aquisição | Não Midriático/Midriático |
| Campo de visão | 50° |
| Distância de trabalho | 13milímetros |
| Tamanho mínimo da pupila | ≥2,8 mm |
| Modo de foco | Automático/Manual |
| Modo de exposição | Automático/Manual |
| Operação | Automático/Manual |
| Fotografia | Câmera SLR |
| Resolução | 5 MegaPixels |
| Compensação de dioptria | ±25D |
| Fixação | Fixação Interna |
| Assistência de foco automático | Câmera dupla |
| DICOM 3.0 | Sim |
| Personalização da porta AI | Sim |
| Dimensões | 28*56*46cm |
| Peso | 21kg |
| Fonte de energia | 100-240V 50/60Hz |
This 3100m fundus camera can be used without dilation of the patient’s eyes, and can also be used with dilated eyes.